Does palsa thaw in Northern Finland contribute to remobilisation of metals accumulated in peat?
Dane / Zasoby
-
Supplementary Material_3.xlsxXLSX
datastore
Błąd
DATA SUPPLEMENT (Supp. Mat. 3) to the manuscript "Does palsa thaw in Northern...
-
Palsa thaw Northern Finlad supplementary material 3XLSX
datastore
Błąd
DATA SUPPLEMENT (Supp. Mat. 3) to the manuscript "Does palsa thaw in Northern...
Dodatkowe Informacje
Pole | Wartość |
---|---|
Nazwa centrum danych | - |
Autorzy |
|
Powiązane publikacje | |
Powiązane projekty | |
Powiązane zbiory danych | |
Kategoria ISO | |
Nazwa kolekcji danych | |
Sposób pozyskiwania danych |
|
Słowa kluczowe GCMD |
|
Data początkowa | 2022-08-17 |
Data końcowa | 2022-08-25 |
Nazwa systemu współrzędnych dla zbioru, EPSG | |
Instrument | EXO2 Multiparameter Sonde YSI, electromagnetic current meter Valeport Model 801, muffle furnace + analytical balance, TOC-VCSH/CSN analyser, TOC-L analyzer with TN-L overlay, L2140-i spectrometer, ICP-OES 9820, ICP-MS 2030, Dionex ICS 3000 |
Opis sprzętu i stanowiska | The multiparameter sonde and electromagnetic current meter were used for measurements conducted in the field, on the dates and locations indicated in the dataset. Further equipment was used to determine concentrations in the collected water and sediment samples, following return from the field. Detailed description of the multiparameter sonde sensors used in the field: 1. EXO Optical Dissolved Oxygen Smart Sensor SKU: 599100-01 Optical, luminescence lifetime 0 to 200%: ±1% of reading or 1% saturation, whichever is greater (w.i.g.) 200 to 500%: ±5% of reading 0 to 20 mg/L: ±0.1 mg/L or 1% of reading, w.i.g. 20 to 50 mg/L: ±5% of reading 0 to 50 mg/L measurement range T63<5 sec response time ±0.1 mg/L or 1% of reading accuracy from 0 to 20 mg/L 2. EXO Turbidity Smart Sensor SKU599101-01 Optical, 90° scatter 0 to 4000 FNU, NTU measurement range T63<2 sec response time 0.3 FNU or ±2% of reading accuracy from 0 to 999 FNU 3. EXO Total Algae PC Smart Sensor SKU599102-01 Optical, fluorescence chlorophyll & phycocyanin Range: Phycocyanin: 0 to 100 RFU, 0 to 100 μg/L Chlorophyll: 0 to 100 RFU, 0 to 400 μg/L Chl Resolution: Phycocyanin: 0.01 RFU, 0.01 μg/L Chlorophyll: 0.01 RFU, 0.01 μg/L Chl 4. EXO pH & ORP Smart Sensor SKU577611 pH: Glass combination electrode ORP: Platinum button pH: ±0.1 pH units within 10°C of calibration temperature ±0.2 pH units for entire temperature range ORP: ±20 mV in Redox standard solution 0 to 14 unit measurement range T63<3 sec response time for pH, T63<5 response time for ORP ±0.1 pH unit accuracy within ±10° C of calibration temperature ±20 mV ORP unit accuracy in Redox standard solutions 5. EXO Conductivity & Temperature Smart Sensor SKU599870 Conductivity Units of Measurement: μS/cm, mS/cm Range: 0 to 200 mS/cm Accuracy: 0 to 100 mS/cm: ±0.5% of reading or 0.001 mS/cm, w.i.g. 100 to 200 mS/cm: ±1% of reading Resolution: 0.0001 to 0.01 mS/cm (range dependent) Response Time: T63<2 sec Sensor Type: 4-electrode nickel cell Temperature Units of Measurement: °C, °F, K Range: -5 to 50°C (23 to 122°F) Accuracy: -5 to 35°C: ±0.01°C 35 to 50°C: ±0.05°C Resolution: 0.001°C Response Time: T63<1 sec Sensor Type: Thermistor Specific Conductance Range: 0 to 200 mS/cm Accuracy: ±0.5% of reading or 0.001 mS/cm, w.i.g. Resolution: 0.001, 0.01, 0.1 mS/cm (auto-scaling) |
Ograniczenia dostępu | Zablokowany |
Źródło | |
DOI zasobu | |
Wersja zasobu | |
Data edycji metadanych | 2025-07-05 |
Nazwisko edytora metadanych | Paweł Kowalski [wyszukaj w katalogu] |
Email edytora metadanych | pawel.kowalski@pw.edu.pl |
Nazwisko kontaktu centrum danych | Krystyna Kozioł |
Email kontaktu centrum danych | krykozio@ukw.edu.pl |